 EMC filters
3-line filters
for converters and power electronics
Rated current 6 to 25 A
Series/Type: Date: B84143A*R206 January 2006
EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the information contained therein without EPCOS' prior express consent is prohibited.
3-line filters for converters and power electronics
Power line filters for 3-phase systems Rated voltage 480/275 V AC, 50/60 Hz Rated current 6 to 25 A Construction
3-line filter Metal case Footprint filter
B84143A*R206
Features
Optimized leakage current
Easy to install
Optimized for long motor cables and operation
under full load
UL approval
Applications
Frequency converters for motor drives, e.g.
- - - -
elevators pumps conveyor systems HVAC systems (heating, ventilation and air conditioning)
Terminals
Line: Finger-safe terminal blocks Load: Litz wires
Marking Marking on component: Manufacturer's logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code Minimum marking on packaging: Manufacturer's logo, ordering code
Upon request the dimensions as well as the fixing points of the filters can be matched to customer requirements. The dimensions shown on the following pages are also available for 1-phase systems up to 22 A.
Please read Cautions and warnings and
Important notes at the end of this document.
2
01/06
3-line filters for converters and power electronics
Typical circuit diagram
LINE
B84143A*R206
LOAD
L1' L2' L3'
L1
L2 L3
SSB1664-T
Technical data and measuring conditions Rated voltage VR Rated current IR Test voltage Vtest Overload capability (thermal) Leakage current lleak Climatic category (IEC 60068-1) Approvals 480/275 V AC, 50/60 Hz Referred to 40 C ambient temperature 1770 V DC, 2 s (line/line) 2700 V DC, 2 s (lines/case) 1.5 * IR for 3 min per hour or 2.5 * IR for 30 s per hour At 480 V AC, 50 Hz 25/100/21 (-25 C/+100 C/21 days damp heat test) UL 1283
Characteristics and ordering codes VR AC V 480/275 IR A 6 12 25 Terminal Ileak cross section mm2 mA 2.5 2.5 4 < 3.5 < 3.5 <6 Rtyp m 72 21 8.5 Approx. weight kg 0.8 1.5 2.3 Ordering code Approvals
B84143A0006R206 B84143A0012R206 B84143A0025R206
x x x
x = approval granted
Please read Cautions and warnings and
Important notes at the end of this document.
3
01/06
3-line filters for converters and power electronics
Dimensional drawings B84143A0006R206 (6 A)
174
B84143A*R206
PE M4
43.5
LINE
Marking
LOAD
3
4 x o4.8
4 x thread M4 x 5
24010 20010
PE
59.60.2
L1 L2 L3
L1' L2' L3'
560.4
73
1600.4
Terminal blocks 2.5 mm 2 Tightening torque 0.5 ... 0.7 Nm
Litz wire Wire end ferrule
1870.5 200
SSB1584-2-E
B84143A0012R206 (12 A)
187 PE M4
43
LINE
Marking
LOAD
2
4 x o4.8
40010 30010
PE L1 L2 L3 L1' L2' L3' Litz wire Wire end ferrule 1740.3 Terminal blocks 2.5 mm 2 Tightening torque 0.5 ... 0.7 Nm 2000.3 213
SSB1585-A-E
1380.3
1200.3
149
4 x thread M4 x 5
Please read Cautions and warnings and
Important notes at the end of this document.
4
01/06
3-line filters for converters and power electronics
B84143A0025R206 (25 A)
B84143A*R206
219
Terminal blocks 4 mm 2 Tightening torque 0.6 ... 0.8 Nm
55
LINE
Marking
LOAD PE M4
2
4 x o5.8
45010 35010
PE L1 L2 L3 L 3' L 2' L 1' Litz wire Wire end ferrule 2040.3 2320.4 245
SSB1586-I-E
1740.3
1560.3
185
4 x thread M5 x 10
Please read Cautions and warnings and
Important notes at the end of this document.
5
01/06
3-line filters for converters and power electronics
Insertion loss (typical values at Z = 50 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 6 A
120 dB B84143A0006R206 100
SSB1581-C
B84143A*R206
Filters for 12 A
120 dB B84143A0012R206 100
SSB1582-K
80
80
60
60
40
40
20
20
0 10 4
10 5
10 6
10 7
Hz 10 8 f
0 10 4
10 5
10 6
10 7
Hz 10 8 f
Filters for 25 A
120 dB B84143A0025R206 100
SSB1583-T
80
60
40
20
0 10 4
10 5
10 6
10 7
Hz 10 8 f
Please read Cautions and warnings and
Important notes at the end of this document.
6
01/06
EMC filters Cautions and warnings
Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appro priate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in low voltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warnings
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such

as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Danger ous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen cies that may cause resonances etc. can lead to destruction of the filter housing. EMC filters must be protected in the application against impermissible exceeding of the rated currents by suitable overcurrent protective.
7
01/06
EMC filters Important notes
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as "hazardous"). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, EPCOS-Jones, Baoke, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
8
01/06


▲Up To Search▲   

 
Price & Availability of B84143A0012R206

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X